Press Transfer Trials: Check Single-Part Pickup, Holding and Release
By EVST Editorial Team · Reviewed by EVST Editorial Team · Last updated October 27, 2026 · Method: video companion · Editorial Policy · Corrections Policy · Terms of Use


An empty-motion demonstration answers only one question: can the mechanism travel through the planned route? A useful press-transfer trial must follow a real part through three separate events—present exactly one part, hold it through the move, and release it where the next operation expects it.
The filmed case shows a blue transfer mechanism moving shallow round metal parts around a green press. Two non-continuous edited excerpts from the same station show the transfer near the tooling, so the trial method below follows the visible part movement rather than treating the edit as one timed cycle.
Start with one-part presentation
If blanks arrive stacked, “the gripper picked something up” is not enough. The trial should distinguish a single blank from two parts travelling together. Ask the integrator to run material from the top, middle and bottom of a representative stack and record what the system detects before it enters the press area.
For a proposed vacuum gripper, cup position, real surface condition and acceleration direction belong in the test. Official handling guidance describes dedicated double-sheet detection, and vacuum-component guidance notes that holding force depends on the application conditions. Apply those checks only when vacuum is part of the proposed concept.
Watch the part, not just the arm
Once a part is acquired, observe whether it changes position relative to the gripper during acceleration, turning and deceleration. Mark a reference on trial parts or use repeatable measurement points so that small shifts are visible. If the concept uses vacuum, test the actual formed surface and pickup locations instead of assuming a flat coupon represents the production part.
Carry the part through the complete approach and withdrawal path. Measure the real envelope of the gripper, part, tooling and nearby structure at the poses that leave the least room. This produces a project-specific clearance record; it is not a universal safety distance or a substitute for the cell risk assessment.
Prove release as a separate event
A part can remain secure during travel yet release late, rebound, or settle differently at the destination. Record the command, the confirmation signal available to the controller, and the observed physical release. Repeat this at the intended placement orientation and with the expected surface condition.
Use a trial sheet that keeps the evidence concrete:
| Trial variable | What to observe | Decision it informs |
|---|---|---|
| Stack position and part variant | One part or more than one presented | Separation and detection concept |
| Pickup location and surface state | Initial acquisition and any shift | Gripper layout and process window |
| Loaded approach and withdrawal | Minimum measured envelope at critical poses | Tooling or path changes |
| Release command and confirmation | Physical release, settling and residual hold | Release method and signal sequence |
| Restart after an abnormal presentation | Detection, recovery action and operator task | Recovery design and operating procedure |
A pass should describe conditions, not impressions
“It ran smoothly” is hard to reuse in engineering. A useful result names the part variant, stack condition, pickup point, motion recipe, placement target and acceptance observation. Failed trials are valuable when they identify which variable must change.
To define a press-transfer trial, send EVST the part shapes at each operation, surface conditions, current pickup method and available tooling space. The discussion can then focus on the feeding conditions that need evidence first: contact EVST.